0:00:00.322,0:00:02.499 When roofing with an open flame 0:00:02.499,0:00:04.902 a gas burner is used. 0:00:04.902,0:00:06.184 It produces long flames and 0:00:06.184,0:00:07.548 can easily start a fire 0:00:07.548,0:00:09.317 in materials nearby, 0:00:09.317,0:00:10.753 or lead warmth 0:00:10.753,0:00:12.833 through cavities, ducts and so on. 0:00:14.934,0:00:17.538 This is especially dangerous in older buildings 0:00:17.538,0:00:19.710 where isolation often consists of 0:00:19.710,0:00:22.547 wood shavings, newspapers or other material 0:00:22.547,0:00:24.095 that can easily ignite. 0:00:24.839,0:00:26.989 Metal can also lead warmth 0:00:26.989,0:00:29.540 and start a fire at a completely different 0:00:29.540,0:00:31.060 place than on the roof. 0:00:31.524,0:00:32.897 Therefore you should bring tools 0:00:32.897,0:00:35.145 you can use to remove planks and tiles with, 0:00:35.145,0:00:37.590 since these places are difficult to reach. 0:00:38.854,0:00:40.584 Roofing with an open flame is also 0:00:40.584,0:00:42.442 regulated in the safety regulation: 0:00:43.394,0:00:45.163 It is prohibitied to use open flame 0:00:45.163,0:00:47.595 on lined and ventilated wooden roofs. 0:00:48.535,0:00:50.852 On compact roofs open flame is permitted 0:00:50.852,0:00:52.888 if flammable insulation is protected with 0:00:52.888,0:00:55.989 at least 30 mm non-combustible insulation. 0:00:57.240,0:00:59.941 There must be a safety distance of 60 cm 0:00:59.941,0:01:03.397 to parapet, cornice, ducts and so on 0:01:03.397,0:01:05.854 if thes consist of combustible material. 0:01:06.794,0:01:09.082 Hot air is a lot safer than 0:01:09.082,0:01:10.342 open flames. 0:01:10.775,0:01:12.263 Here the warm gas and air is 0:01:12.263,0:01:13.916 shielded in a chamber. 0:01:13.916,0:01:15.885 The biggest risk with this equipment 0:01:15.885,0:01:18.584 is that it produces a lot of carbon dioxide 0:01:18.584,0:01:19.896 that displaces the oxygen. 0:01:20.506,0:01:22.629 When you are done and turn off the equipment 0:01:22.629,0:01:24.165 oxygen-rich air rushes back, 0:01:24.165,0:01:27.594 which can lead to ignition. 0:01:29.188,0:01:32.107 Roofing can also be done with hot bitumen. 0:01:32.107,0:01:34.369 Gas-fired bitumen boilers are used 0:01:34.369,0:01:36.875 in order to heat the asphalt to 200 degrees celcius. 0:01:36.875,0:01:39.135 Here the bitumen boiler is the main risk, 0:01:39.135,0:01:40.720 not the roofing. 0:01:41.074,0:01:42.456 It can overheat, 0:01:42.456,0:01:44.000 causing the bitumen to ignite. 0:01:44.000,0:01:46.909 Or warm bitumen can spray out of the boiler. 0:01:48.429,0:01:51.848 When using a bitumen boiler you must follow these rules: 0:01:52.838,0:01:54.850 The bitumen boiler must be placed on a non-combustible 0:01:54.850,0:01:56.046 and level base, 0:01:56.046,0:01:57.386 for example in a vessel, 0:01:57.386,0:01:58.903 that can hold at least half of the 0:01:58.903,0:02:00.455 content in the boiler and is at least 0:02:00.455,0:02:03.326 30 cm wider than the boiler on all sides. 0:02:04.143,0:02:05.460 The boiler must always be placed 0:02:05.460,0:02:07.432 where it cause the least possible risk 0:02:07.432,0:02:09.639 if it overheats or tips over. 0:02:10.457,0:02:13.240 The boiler must be supervised at all times. 0:02:14.460,0:02:16.997 Flammable material in the vicinity must be removed. 0:02:18.254,0:02:20.610 On sloping grounds the boiler must be at least 0:02:20.610,0:02:23.090 15 meters from flammable material. 0:02:24.040,0:02:26.492 And at least 5 meters from 0:02:26.492,0:02:29.368 buildings in non-combustible materials. 0:02:30.462,0:02:32.022 Gas cylinders must be placed at 0:02:32.022,0:02:34.231 least 5 metes from the boiler. 0:02:35.509,0:02:36.717 Fire in a boiler must 0:02:36.717,0:02:38.362 never be put out with water. 0:02:38.362,0:02:39.634 If water comes in contact with 0:02:39.634,0:02:40.738 the burning bitument, 0:02:40.738,0:02:42.679 it can be thrown out of the boiler 0:02:42.679,0:02:44.671 with great power.