1 00:00:00,322 --> 00:00:02,499 When roofing with an open flame 2 00:00:02,499 --> 00:00:04,902 a gas burner is used. 3 00:00:04,902 --> 00:00:06,184 It produces long flames and 4 00:00:06,184 --> 00:00:07,548 can easily start a fire 5 00:00:07,548 --> 00:00:09,317 in materials nearby, 6 00:00:09,317 --> 00:00:10,753 or lead warmth 7 00:00:10,753 --> 00:00:12,833 through cavities, ducts and so on. 8 00:00:14,934 --> 00:00:17,538 This is especially dangerous in older buildings 9 00:00:17,538 --> 00:00:19,710 where isolation often consists of 10 00:00:19,710 --> 00:00:22,547 wood shavings, newspapers or other material 11 00:00:22,547 --> 00:00:24,095 that can easily ignite. 12 00:00:24,839 --> 00:00:26,989 Metal can also lead warmth 13 00:00:26,989 --> 00:00:29,540 and start a fire at a completely different 14 00:00:29,540 --> 00:00:31,060 place than on the roof. 15 00:00:31,524 --> 00:00:32,897 Therefore you should bring tools 16 00:00:32,897 --> 00:00:35,145 you can use to remove planks and tiles with, 17 00:00:35,145 --> 00:00:37,590 since these places are difficult to reach. 18 00:00:38,854 --> 00:00:40,584 Roofing with an open flame is also 19 00:00:40,584 --> 00:00:42,442 regulated in the safety regulation: 20 00:00:43,394 --> 00:00:45,163 It is prohibitied to use open flame 21 00:00:45,163 --> 00:00:47,595 on lined and ventilated wooden roofs. 22 00:00:48,535 --> 00:00:50,852 On compact roofs open flame is permitted 23 00:00:50,852 --> 00:00:52,888 if flammable insulation is protected with 24 00:00:52,888 --> 00:00:55,989 at least 30 mm non-combustible insulation. 25 00:00:57,240 --> 00:00:59,941 There must be a safety distance of 60 cm 26 00:00:59,941 --> 00:01:03,397 to parapet, cornice, ducts and so on 27 00:01:03,397 --> 00:01:05,854 if thes consist of combustible material. 28 00:01:06,794 --> 00:01:09,082 Hot air is a lot safer than 29 00:01:09,082 --> 00:01:10,342 open flames. 30 00:01:10,775 --> 00:01:12,263 Here the warm gas and air is 31 00:01:12,263 --> 00:01:13,916 shielded in a chamber. 32 00:01:13,916 --> 00:01:15,885 The biggest risk with this equipment 33 00:01:15,885 --> 00:01:18,584 is that it produces a lot of carbon dioxide 34 00:01:18,584 --> 00:01:19,896 that displaces the oxygen. 35 00:01:20,506 --> 00:01:22,629 When you are done and turn off the equipment 36 00:01:22,629 --> 00:01:24,165 oxygen-rich air rushes back, 37 00:01:24,165 --> 00:01:27,594 which can lead to ignition. 38 00:01:29,188 --> 00:01:32,107 Roofing can also be done with hot bitumen. 39 00:01:32,107 --> 00:01:34,369 Gas-fired bitumen boilers are used 40 00:01:34,369 --> 00:01:36,875 in order to heat the asphalt to 200 degrees celcius. 41 00:01:36,875 --> 00:01:39,135 Here the bitumen boiler is the main risk, 42 00:01:39,135 --> 00:01:40,720 not the roofing. 43 00:01:41,074 --> 00:01:42,456 It can overheat, 44 00:01:42,456 --> 00:01:44,000 causing the bitumen to ignite. 45 00:01:44,000 --> 00:01:46,909 Or warm bitumen can spray out of the boiler. 46 00:01:48,429 --> 00:01:51,848 When using a bitumen boiler you must follow these rules: 47 00:01:52,838 --> 00:01:54,850 The bitumen boiler must be placed on a non-combustible 48 00:01:54,850 --> 00:01:56,046 and level base, 49 00:01:56,046 --> 00:01:57,386 for example in a vessel, 50 00:01:57,386 --> 00:01:58,903 that can hold at least half of the 51 00:01:58,903 --> 00:02:00,455 content in the boiler and is at least 52 00:02:00,455 --> 00:02:03,326 30 cm wider than the boiler on all sides. 53 00:02:04,143 --> 00:02:05,460 The boiler must always be placed 54 00:02:05,460 --> 00:02:07,432 where it cause the least possible risk 55 00:02:07,432 --> 00:02:09,639 if it overheats or tips over. 56 00:02:10,457 --> 00:02:13,240 The boiler must be supervised at all times. 57 00:02:14,460 --> 00:02:16,997 Flammable material in the vicinity must be removed. 58 00:02:18,254 --> 00:02:20,610 On sloping grounds the boiler must be at least 59 00:02:20,610 --> 00:02:23,090 15 meters from flammable material. 60 00:02:24,040 --> 00:02:26,492 And at least 5 meters from 61 00:02:26,492 --> 00:02:29,368 buildings in non-combustible materials. 62 00:02:30,462 --> 00:02:32,022 Gas cylinders must be placed at 63 00:02:32,022 --> 00:02:34,231 least 5 metes from the boiler. 64 00:02:35,509 --> 00:02:36,717 Fire in a boiler must 65 00:02:36,717 --> 00:02:38,362 never be put out with water. 66 00:02:38,362 --> 00:02:39,634 If water comes in contact with 67 00:02:39,634 --> 00:02:40,738 the burning bitument, 68 00:02:40,738 --> 00:02:42,679 it can be thrown out of the boiler 69 00:02:42,679 --> 00:02:44,671 with great power.